Scene restore:
Industrial control equipment ’s control board – the transformer is only responsible for supplying power to the MCU and display panel; its power output is relatively small (5–15 W), but the requirements are extremely stringent: it must operate continuously for 24 hours without interruption, function across a wide temperature range from −40°C to 85°C, and maintain voltage fluctuations below 5%.
Many buyers see 5W, 8W demand, casually choose a cheap EE13 or even smaller core, think the power is enough on the line. And what happened?
The scene of the rollover:
· No-load output jump, MCU occasionally reset
· The inductor decays in high temperature environment and the output voltage is unstable
· The initial burst current is large, the transformer is saturated, and the strike is direct
Selection Key:
The control board needs to be "stable," not "big."
Watt’s solution : EE14 –The “voltage regulator” on the control panel
Watt Smart EE14 , Ae = 24.82 mm²,The power is 5-8W, which exactly covers the typical requirements of the control board auxiliary power supply.The PC40 ferrite core maintains a Bsat value of more than 0.35 T even at 100°C; the Bmax operating point is kept below 0.3 T, and the flyback topology has ample saturation margin。Its compact package measures 16 × 15 × 11 mm – so small that it can fit even into the tightest control‑board spaces.